• Hydrogen Technologies Standards form the basic framework for market ramp-up

    More information
  • Climate change Standards and specifications support climate targets

    More information
  • Smart Farming Standards and specifications are drivers for the digitalization of agriculture

    More information
Project

Energy performance of buildings - Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads - Part 3: Calculation procedures regarding adaptive building envelope elements - Amendment 1: Reference control scenarios for adaptive building envelope elements with active solar shading or chromogenic glazing (ISO 52016-3:2023/DAM 1:2024); German and English version EN ISO 52016-3:2023/prA1:2024

Abstract

This document specifies procedures for the calculation of the energy needs for heating and cooling, internal temperatures and sensible and latent heat loads of a building according to the hourly calculation methodology in ISO 52016-1. Additions or modifications of the calculations are provided in this document if the building envelope contains one or more adaptive building envelope elements (building envelope elements with adaptive components that are either environmentally or actively controlled as a function of specific conditions). The adaptive building envelope element replaces the transparent building element in the calculation according to ISO 52016-1. The three types of adaptive building envelope elements covered in this document are: — building envelope elements with dynamic solar shading; — building envelope elements with chromogenic glazing; — building envelope elements with an actively ventilated cavity. Environmentally activated control is described for building envelope elements with chromogenic glazing, but can also occur for other types of adaptive building envelope elements. In that case the same approach applies as for environmentally activated chromogenic glazing. This document is applicable to the assessment of the energy performance of buildings (EPB) (energy performance labels and certificates), including comparison between buildings and checking conformity with minimum energy performance criteria. It is also applicable to assess the contribution of the adaptive building envelope element to the smart readiness of a building. In addition, this document provides indicators for the impact of the adaptive building envelope element on the performance of the building compared to a reference building envelope element. It is applicable to buildings at the design stage, to new buildings after construction and to existing buildings in the use phase. This document is not applicable to geometrically complex adaptive building envelope elements that can only be modelled as multiple coupled thermal zones. NOTE The background to the selection of adaptive building envelope elements is given in ISO/TR 52016-4.

Begin

2024-03-06

WI

00089218

Planned document number

DIN EN ISO 52016-3/A1

Project number

00519751

Responsible national committee

NA 005-12-01 GA - Joint working committee NABau/FNL/NHRS: Energy efficiency of buildings (national mirror committee for CEN/TC 371, CEN/TC 371/WG 1, CEN/TC 371/WG 2, CEN/TC 371/WG 3, CEN/TC 371/WG 4, CEN/TC 371/WG 5, ISO/TC 163/WG 4 und ISO/TC 163/SC 2/WG 15)  

Responsible european committee

CEN/TC 89 - Thermal performance of buildings and building components  

Responsible international committee

ISO/TC 163/SC 2/WG 15 - Energy Performance calculation methods  

draft standard

Energy performance of buildings - Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads - Part 3: Calculation procedures regarding adaptive building envelope elements - Amendment 1: Reference control scenarios for adaptive building envelope elements with active solar shading or chromogenic glazing (ISO 52016-3:2023/DAM 1:2024); German and English version EN ISO 52016-3:2023/prA1:2024
2025-02
Order from DIN Media

previous edition(s)

Energy performance of buildings - Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads - Part 3: Calculation procedures regarding adaptive building envelope elements (ISO 52016-3:2023); German version EN ISO 52016-3:2023
2024-07

Order from DIN Media

Contact

M.Sc.

Anne Lina Wehrle

Am DIN-Platz, Burggrafenstr. 6
10787 Berlin

Tel.: +49 30 2601-2478
Fax: +49 30 2601-42478

Send message to contact